WATER QUALITY PROBLEM
Hardness salts, Ca and Mg form scale deposits on heat exchangers, nozzles, fittings, pipes, sanitary facilities. Fine technical equipment rapidly out of order or increasing power consumption.
SOLUTION
The solution of these problems for households is softening by WATEX CMS CAB GRAY SLIM ion exchange resin filters (reduces limescale) that are regenerated with NaCl. Water softening equipment also effectively reduce iron, manganese and ammonium.
FILTER PERFORMANCE
For recovery of filtration media (ion resins) reagent (NaCl or salt tablets) is used. Wastewaters produced in regeneration processes of equipment of WATEX CMS CAB GRAY SLIM can be directly discharged to biological wastewater treatment plant. WATEX CMS CAB GRAY SLIM consists of a filter column, control valve and salt tank. The filter column is filled with ion exchange resin (cationic), which reduces hardness and iron concentration in water. The control valve performs automatic regeneration. Salt tank is filled with a reagent (NaCl, salt tablets) for resin regeneration. Capacity of filtration media is calculated according to amount of resins and raw water quality.
FILTER CONTROL
WATEX CMS CAB GRAY SLIM is equipped with a Clack WSCI1 control valve, with a built-in flow meter that performs filtration media regeneration according to water consumption. Flowmeter saves water and salt used for filter regeneration. The valve can be fitted with a bypass pipeline that allows to perform maintenance works with ease. Control valve saves all information in case of power failure. Equipment has many parameters that can be adjusted according to needs, such as washing time, frequency, reagent consumption, and so on.
Technical parameters of equipment |
Unit |
Model |
|
CMS CAB GRAY SLIM |
CMS CAB GRAY |
||
Flow rate nominal |
m3/h |
0,5 |
0,8 |
Flow rate maximum |
m3/h |
2,0 |
2,5 |
Minimum flow rate for rinsing |
m3/h |
0,41 |
0,41 |
Tank size |
inches |
8x35 |
10x35 |
Tank volume |
liters |
25 |
39 |
The amount of filtering material |
liters |
18 |
25 |
Required water for filter regeneration |
liters |
70 |
84 |
Filter capacity between regeneration (5mg-ekv/l) |
liters |
4600 |
6400 |
The average salt consumption for regeneration |
kg |
2,50 |
3,84 |
Dimensions |
|||
Length |
cm |
47 |
57 |
Width |
cm |
26 |
33 |
Height |
cm |
108 |
108 |
Connection. In-out-drain |
3/4''-3/4''-3/4'' |
1''-1’’-3/4'' |
|
Clack control unit |
CI 1'' |
||
Filtration |
Ca2+, Mg2+ (Limescale), Fe2+, Mn2+ (Rust&Stains) |
||
Regeneration |
By Salt NaCl |
||
Container material |
FRP (fiberglass) |
||
Filtering material |
Ion exchange resins RESINEX KW-8 |
||
Operating pressure |
bar |
2-6 |
|
Electric Connection |
220V, 50Hz, 1 phase |
||
Electricity consumption |
W |
3 W |
EQUIPMENT MAINTENANCE
Although the equipment uses salt tablets for regeneration it is safe to use filtered water for drinking and other human needs. It is necessary to provide electricity connection power (one socket), sewerage drainage and incoming / outgoing water supply with minimum pressure of 2.5 bar.
RECOMMENDATIONS
Additional equipment options:
Width cm |
Height cm |
Length cm |
Weight kg |
---|---|---|---|
27.00 |
110.00 |
45.00 |
50.00 |
By clicking on the following links, you can view and download:
Water_softening_solutions_WATEX_ENG.pdf